Technischer Taschenrechner

Voltage Coefficient (VCR) Error Calculator

FrR1(V)VoutR20 VR0VRR(V)dR/R

Wie man das Diagramm liest. The top resistor changes value as the voltage across it rises, so the ratio at 20 kV is not the ratio you measured on the bench. The curve is that drift and dR/R is the error the calculator returns.

A thick film resistor is not the same value at 20 kV as on a bench meter. VCR is quoted in ppm per volt; this turns it into the resistance change and the divider error it causes.

Eingänge

Ergebnisse

R1 change
-
Ratio at 0 V
-
Ratio at working V
-
Verhältnisfehler
-
Output at working V
-

Die Formel

ΔR/R = VCR × V / 1,000,000. Divider ratio = (R1 + R2) / R2; recalculate it with the shifted R1 to get the error.

Was der Rechner nicht beinhaltet

Auswahl der Teile

Where the ratio matters, specify VCR explicitly: the planarer Dickschichtbereich is quoted for precision divider use, tolerance from 0.2%. For matched pairs, send the ratio and the voltage.

Send the calculated values and the duty: Fordern Sie ein technisches Angebot an, response within 6 hours.