Austauschleitfaden / HVCA
HVCA, EDI, 산켄 의 고전압 다이오드 대체품
HVCA, EDI, 산켄 의 고전압 다이오드 대체품

TEILENUMMER-QUERVERWEIS
HVCA| Artikelnummer | HVC-Alternative | VRRM | IO | trr |
|---|---|---|---|---|
| DV6P | HVD-SL6G75 | 6KV | 75 mA | 75ns |
| DV8P | HVD-SL8G60 | 8KV | 60 mA | 75ns |
| DV10P | HVD-SL10G55 | 10KV | 55 mA | 75ns |
| G6FS | HVD-SL6G25 | 6KV | 25 mA | 100ns |
| G7FS | HVD-SL7G25 | 7KV | 25 mA | 100ns |
| G8FS | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| G10FS | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| G12FS | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| G15FS | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| G20FS | HVD-SL20G25 | 20KV | 25 mA | 100ns |
| G25FS | HVD-SL25G25 | 25KV | 25 mA | 100ns |
| G30FS | HVD-SL30G25 | 30KV | 25 mA | 100ns |
| G2FSA | HVD-SL2G25 | 2KV | 25 mA | 75ns |
| G3FSA | HVD-SL3G25 | 3KV | 25 mA | 75ns |
| G4FSA | HVD-SL4G25 | 4KV | 25 mA | 75ns |
| G5FSA | HVD-SL5G25 | 5KV | 25 mA | 75ns |
| HL300 | HVD-SL3G40 | 3KV | 40 mA | 100ns |
| HL500 | HVD-SL5G40 | 5KV | 40 mA | 100ns |
| HL800 | HVD-SL8G40 | 8KV | 40 mA | 100ns |
| HL1000 | HVD-SL10G40 | 10KV | 40 mA | 100ns |
| HL1200 | HVD-SL12G40 | 12KV | 40 mA | 100ns |
| HVEF8P | - | 8KV | 30 mA | 20ns |
| HVEF10P | - | 10KV | 20 mA | 20ns |
| HVEF12P | - | 12KV | 20 mA | 20ns |
| NV20FP | HVD-SL2G20 | 2KV | 20 mA | 80ns |
| NV30FP | HVD-SL3G20 | 3KV | 20 mA | 80ns |
| NV40FP | HVD-SL4G20 | 4KV | 20 mA | 80ns |
| NV50FP | HVD-SL5G20 | 5KV | 20 mA | 80ns |
| HVRT080 | HVD-SL8G30 | 8KV | 30 mA | 100ns |
| HVRT120 | HVD-SL12G30 | 12KV | 30 mA | 100ns |
| HVRT150 | HVD-SL15G30 | 15KV | 30 mA | 100ns |
| HVRT200 | HVD-SL20G30 | 20KV | 30 mA | 100ns |
| HVRT250 | HVD-SL25G30 | 25KV | 30 mA | 100ns |
| HVRT300 | HVD-SL30G30 | 30KV | 30 mA | 100ns |
| HVRL150 | HVD-SL15G30 | 15KV | 30 mA | 100ns |
| HVRL200 | HVD-SL20G30 | 20KV | 30 mA | 100ns |
| HVRL250 | HVD-SL25G30 | 25KV | 30 mA | 100ns |
| HVRL300 | HVD-SL30G30 | 30KV | 30 mA | 100ns |
| HVRL400 | HVD-SL40G30 | 40KV | 30 mA | 100ns |
| HV07-12B | HVD-SL312 | 12KV | 225 mA | / |
| HV37-08 | HVD-SL308G | 8KV | 210 mA | 150ns |
| HV37-08F | HVD-SL208G | 8KV | 210 mA | 50ns |
| HV37-10 | HVD-SL310G | 10KV | 190 mA | 150ns |
| HV37-10F | HVD-SL310GF | 10KV | 190 mA | 120ns |
| HV37-12 | HVD-SL312G | 12KV | 250 mA | 100ns |
| HV37-12F | HVD-SL312GF | 12KV | 300 mA | 80ns |
| HV37-20 | HVD-SL220G | 20KV | 200 mA | 100ns |
| HV37-20F | HVD-SL220GF | 20KV | 200 mA | 80ns |
| CL03-08 | HVD-SL03-08 | 8KV | 400 mA | 100ns |
| CL03-10 | HVD-SL03-10 | 10KV | 300 mA | 100ns |
| CL03-12 | HVD-SL03-12 | 12KV | 250 mA | 100ns |
| CL03-15 | HVD-SL03-15 | 15KV | 200 mA | 100ns |
| CL03-20 | HVD-SL03-20 | 20KV | 120 mA | 100ns |
| CL03-30 | HVD-SL03-30 | 30KV | 120 mA | 100ns |
| 2CL2FF | HVD-2CL2FF | 8KV | 60 mA | 150ns |
| 2CL2F | HVD-2CL2F | 8KV | 100 mA | / |
| 2CL2FG | HVD-2CL2FG | 10KV | 60 mA | 150ns |
| 2CL2G | HVD-2CL2G | 10KV | 100 mA | / |
| 2CL2FK | HVD-2CL2FK | 10KV | 140 mA | 100ns |
| 2CL2FH | HVD-2CL2FH | 12KV | 60 mA | 150ns |
| 2CL2H | HVD-2CL2H | 12KV | 100 mA | / |
| 2CL2FJ | HVD-2CL2FJ | 15KV | 60 mA | 150ns |
| 2CL2J | HVD-2CL2J | 15KV | 100 mA | / |
| 2cl2fl | HVD-2CL2FL | 15KV | 120 mA | 100ns |
| 2CL2FM | HVD-2CL2FM | 20KV | 100 mA | / |
| 2CL2FP | HVD-2CL2FP | 30KV | 140 mA | 100ns |
| 2CL2FR | HVD-2CL2FR | 35KV | 100 mA | 100ns |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| UX-FBR8 | HVD-2CL8KV / 420 mA | 8KV | 420 mA | / |
| UX-F2CL15 | HVD-2CLG15KV / 150 mA | 15KV | 150 mA | 50ns |
| UX-F15B | HVD-2CLG15KV / 200 mA | 15KV | 200 mA | 50ns |
| UX-F30B | HVD-2CLG30KV / 100 mA | 30KV | 100 mA | 50ns |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| BR2F | HVD-SL2F | 2KV | 900 mA | 100ns |
| BR2 | HVD-SL2 | 2KV | 1000 mA | / |
| BR3F | HVD-SL3F | 3KV | 900 mA | 100ns |
| BR4F | HVD-SL4F | 4KV | 600 mA | 100ns |
| BR4 | HVD-SL4 | 4KV | 850 mA | / |
| BR5F | HVD-SL5F | 5KV | 600 mA | 100ns |
| BR6F | HVD-SL6F | 6KV | 500 mA | 100ns |
| BR8F | HVD-SL8F | 8KV | 400 mA | 100ns |
| BR10F | HVD-SL10F | 10KV | 250 mA | 100ns |
| BRU10SF | HVD-SLU10SF | 10KV | 250 mA | 75ns |
| HV200UF3 | HVD-SL200UF3 | 3KV | 375 mA | 50ns |
| HV200UF4 | HVD-SL200UF4 | 4KV | 375 mA | 50ns |
| HV200UF5 | HVD-SL200UF5 | 5KV | 375 mA | 50ns |
| HV550S08 | HVD-HV600S08 | 8KV | 550 mA | / |
| HV550S10 | HVD-HV600S10 | 10KV | 450 mA | / |
| HV550S12 | HVD-HV600S12 | 12KV | 400 mA | / |
| HV550S15 | HVD-HV600S15 | 15KV | 350 mA | / |
| HV550S20 | HVD-HV600S20 | 20KV | 250 mA | / |
| HV550S25 | HVD-HV600S25 | 25KV | 200 mA | / |
| HV550S30 | HVD-HV600S30 | 30KV | 200 mA | / |
| HV550S45 | HVD-HV600S45 | 45KV | 100 mA | / |
| HVCF25 | HVD-2CLG2.5KV / 1.5A | 2.5KV | 1500 mA | 75ns |
| HVCF50 | HVD-2CLG5KV / 1.2A | 5KV | 1200 mA | 75ns |
| HVCF100 | HVD-2CLG10KV / 0.65A | 10KV | 650 mA | 75ns |
| HVRW1 | HVD-HVRW1 | 1KV | 2500 mA | 150ns |
| HVRW2 | HVD-HVRW2 | 2KV | 1500 mA | 150ns |
| HVRW3 | HVD-HVRW3 | 3KV | 1500 mA | 150ns |
| HVRW4 | HVD-HVRW4 | 4KV | 1000 mA | 150ns |
| HVW3 | HVD-HVRM3 | 3KV | 2000 mA | / |
| UFHV2K | HVD-SL2G550 | 2KV | 550 mA | 75ns |
| UFHV3K | HVD-SL3G400 | 3KV | 400 mA | 75ns |
| UFHV4K | HVD-SL4G350 | 4KV | 350 mA | 75ns |
| EF100 | HVD-SLF100 | 1KV | 600 mA | / |
| EF150 | HVD-SLF150 | 1.5KV | 600 mA | / |
| EF200 | HVD-SLF200 | 2KV | 600 mA | / |
| EG200 | HVD-SLG200 | 2KV | 400 mA | / |
| EG250 | HVD-SLG250 | 2.5KV | 400 mA | / |
| EG300 | HVD-SLG300 | 3KV | 400 mA | / |
| EH300 | HVD-SLH300 | 3KV | 300 mA | / |
| EH350 | HVD-SLH350 | 3.5KV | 300 mA | / |
| EH400 | HVD-SLH400 | 4KV | 300 mA | / |
| EK450 | HVD-SLH450 | 4.5KV | 200 mA | / |
| EK500 | HVD-SLH500 | 5KV | 200 mA | / |
| EK600 | HVD-SLH600 | 6KV | 200 mA | / |
| EM700 | HVD-SLM700 | 7KV | 175 mA | / |
| EM800 | HVD-SLM800 | 8KV | 175 mA | / |
| EP2016 | - | 9KV | 150 mA | / |
| EP2016 | - | 10KV | 150 mA | / |
| ER1100 | HVD-SLP1100 | 11KV | 100 mA | / |
| ER1200 | HVD-SLP1200 | 12KV | 100 mA | / |
| RF160B | HVD-SLF160B | 1.6KV | 500 mA | 250ns |
| RF200B | HVD-SLF200B | 2KV | 500 mA | 250ns |
| RG300B | HVD-SLG300B | 3KV | 350 mA | 250ns |
| RK300B | HVD-SLK300B | 3KV | 150 mA | 250ns |
| RK400B | HVD-SLK400B | 4KV | 150 mA | 250ns |
| RK500B | HVD-SLK500B | 5KV | 150 mA | 250ns |
| RK600B | HVD-SLK600B | 6KV | 150 mA | 250ns |
| RM700B | HVD-SLM700B | 7KV | 125 mA | 250ns |
| RM800B | HVD-SLM800B | 8KV | 125 mA | 250ns |
| RP900B | HVD-SLP900B | 9KV | 100 mA | 250ns |
| RP1000B | HVD-SLP1000B | 10KV | 100 mA | 250ns |
| RR1100B | HVD-SLP1100B | 11KV | 80 mA | 250ns |
| RR1200B | HVD-SLP1200B | 12KV | 80 mA | 250ns |
| RF160A | HVD-SLF160A | 1.6KV | 500 mA | 150ns |
| RF200A | HVD-SLF200A | 2KV | 500 mA | 150ns |
| RG300A | HVD-SLG300A | 3KV | 350 mA | 150ns |
| RK300A | HVD-SLK300A | 3KV | 150 mA | 150ns |
| RK400A | HVD-SLK400A | 4KV | 150 mA | 150ns |
| RK500A | HVD-SLK500A | 5KV | 150 mA | 150ns |
| RK600A | HVD-SLK600A | 6KV | 150 mA | 150ns |
| RM800A | HVD-SLM800A | 8KV | 125 mA | 150ns |
| RP1000A | HVD-SLP1000A | 10KV | 100 mA | 150ns |
| RR1200A | HVD-SLR100A | 12KV | 80 mA | 150ns |
| FB4 | HVD-SL4 | 4KV | 2A | / |
| FB5 | HVD-SL5 | 5KV | 2A | / |
| FBR3 | HVD-SLR3 | 3KV | 1.5A | 250ns |
| FBR3.5 | HVD-SLR3.5 | 3.5KV | 1.5A | 250ns |
| FBR4 | HVD-SLR4 | 4KV | 1.5A | 250ns |
| 3W2 | HVD-HVRM2 | 2KV | 2A | / |
| 3W2.5 | HVD-HVRM2.5 | 2.5KV | 2A | / |
| 3W3 | HVD-HVRM3 | 3KV | 2A | / |
| 3RW2 | HVD-HVRW2 | 2KV | 1.5A | 250ns |
| 3RW2.5 | HVD-HVRW2.5 | 2.5KV | 1.5A | 250ns |
| 3RW3 | HVD-HVRW3 | 3KV | 1.5A | 250ns |
| XL10 | HVD-SL10 | 9KV | 220 mA | / |
| XLR5 | HVD-SLR5 | 5KV | 200 mA | 175ns |
| XLR10 | HVD-SLR10 | 9KV | 200 mA | 175ns |
| XLU12 | HVD-SLU12 | 11KV | 100 mA | 50ns |
| XLR20 | HVD-SLR20 | 18KV | 100 mA | 175ns |
| 5 | - | 5KV | 500 mA | 150ns |
| XMU5 | HVD-SLMU5 | 5KV | 300 mA | 75ns |
| XMU10 | HVD-SLMU10 | 9KV | 300 mA | 75ns |
| DR300 | HVD-SL3G25 | 3KV | 25 mA | 100ns |
| DR500 | HVD-SL5G25 | 5KV | 25 mA | 100ns |
| DR800 | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| DR1000 | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| DR1200 | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| DR1500 | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| DL300 | HVD-SL3G25 | 3KV | 25 mA | 150ns |
| DL500 | HVD-SL5G25 | 5KV | 25 mA | 150ns |
| DL800 | HVD-SL8G25 | 8KV | 25 mA | 150ns |
| DL1000 | HVD-SL10G25 | 10KV | 25 mA | 150ns |
| DL1200 | HVD-SL12G25 | 12KV | 25 mA | 150ns |
| QR12 | HVD-2CL73 | 12KV | 6 mA | 100ns |
| TV6 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| TV8 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| TV10 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| TV12 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| TV14 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| TV16 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| TV20 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| TVR30 | HVD-2CL82 | 30KV | 10 mA | 100ns |
| RUSH103 | HVD-SL200UF3 | 3KV | 200 mA | 50ns |
| RUSH104 | HVD-SL200UF4 | 4KV | 200 mA | 50ns |
| RUSH105 | HVD-SL200UF5 | 5KV | 200 mA | 50ns |
| VT1000 | HVD-SL1000 | 10KV | 50 mA | / |
| VT1200 | HVD-SL1200 | 12KV | 50 mA | / |
| VT1500 | HVD-SL1500 | 15KV | 50 mA | / |
| RVT1000 | HVD-SL10G50 | 10KV | 50 mA | 100ns |
| RVT1200 | HVD-SL12G50 | 12KV | 50 mA | 100ns |
| RVT1500 | HVD-SL15G50 | 15KV | 50 mA | 100ns |
| ROST2008 | - | 8KV | 100 mA | 50ns |
| ROST2010 | - | 10KV | 100 mA | 50ns |
| CRVT150 | HVD-SL15G25B | 15KV | 25 mA | 100ns |
| CRVT200 | HVD-SL20G25B | 20KV | 25 mA | 100ns |
| CRVT250 | HVD-SL25G25B | 25KV | 25 mA | 100ns |
| CRVT300 | HVD-SL30G25B | 30KV | 25 mA | 100ns |
| SL300 | HVD-SL3G40 | 3KV | 40 mA | 100ns |
| SL500 | HVD-SL5G40 | 5KV | 40 mA | 100ns |
| SL800 | HVD-SL8G40 | 8KV | 40 mA | 100ns |
| SL1000 | HVD-SL10G40 | 10KV | 40 mA | 100ns |
| SL1200 | HVD-SL12G40 | 12KV | 40 mA | 100ns |
| SR300 | HVD-SL3G25 | 3KV | 25 mA | 100ns |
| SR500 | HVD-SL5G25 | 5KV | 25 mA | 100ns |
| SR800 | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| SR1000 | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| SR1200 | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| SR1500 | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| 2CL69 | HVD-2CL69 | 4KV | 5 mA | 100ns |
| 2CL70 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| 2CL71 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| 2CL72 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| 2CL73 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| 2CL74 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| 2CL75 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| 2CL76 | HVD-2CL76 | 18KV | 5 mA | 100ns |
| 2CL77 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| 2CL103 | HVD-2CL103 | 9KV | 350 mA | / |
| 2CL104 | HVD-2CL104 | 12KV | 350 mA | / |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| R3000 | HVD-R3000 | 3KV | 200 mA | / |
| R3000F | HVD-R3000F | 3KV | 200 mA | / |
| R4000 | HVD-R4000 | 4KV | 200 mA | / |
| R4000F | HVD-R4000F | 4KV | 200 mA | / |
| R5000 | - | 5KV | 200 mA | / |
| R5000F | HVD-R5000F | 5KV | 200 mA | / |
| RFC3K | HVD-R3000 | 3KV | 200 mA | / |
| RFC4K | HVD-R4000 | 4KV | 200 mA | / |
| 2CL4 | HVD-2CL69 | 4KV | 5 mA | 100ns |
| 2CL6 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| 2CL8 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| 2CL10 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| 2CL12 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| 2CL14 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| 2CL16 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| 2CL20 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| 2CL703 | HVD-2CL703 | 3KV | 5 mA | 80ns |
| 2CL704 | HVD-2CL704 | 4KV | 5 mA | 80ns |
| T71A | HVD-2CLT71 | 8KV | 5 mA | 80ns |
| T72A | HVD-2CLT72 | 10KV | 5 mA | 80ns |
| T73A | HVD-2CLT73 | 12KV | 5 mA | 80ns |
| T74A | HVD-2CLT74 | 14KV | 5 mA | 80ns |
| T75A | HVD-2CLT75 | 16KV | 5 mA | 80ns |
| TG3508 | HVD-SL3508G | 8KV | 350 mA | 150ns |
| TS01 | HVD-SL3506 | 6KV | 350 mA | / |
| UX-C2B | - | 8KV | 500 mA | 35ns |
| T3512H | HVD-2CL3512 | 12KV | 350 mA | / |
| T4512H | HVD-2CL4512 | 12KV | 450 mA | / |
| T3509 | HVD-2CL3509 | 9KV | 350 mA | / |
| T4509 | HVD-2CL4509 | 9KV | 450 mA | / |
| 2CL3512H | HVD-2CL3512 | 12KV | 350 mA | / |
| 2CL4512H | HVD-2CL4512 | 12KV | 450 mA | / |
| BR2 | HVD-SL2 | 2KV | 1000 mA | / |
| BR4 | HVD-SL4 | 4KV | 1000 mA | / |
| TG1015 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| SHV049 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| 2CLG1015 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| DD2000 | HVD-SL30F10 | 30KV | 10 mA | / |
| JB99 | HVD-2CL20KV / 20 mA | 20KV | 20 mA | 100ns |
| JB99T | HVD-2CL20KV / 20 mA | 20KV | 20 mA | 100ns |
| DV6P | HVD-SL6G75 | 6KV | 75 mA | 75ns |
| DV8P | HVD-SL8G60 | 8KV | 60 mA | 75ns |
| DV10P | HVD-SL10G55 | 10KV | 55 mA | 75ns |
| G6FS | HVD-SL6G25 | 6KV | 25 mA | 100ns |
| G7FS | HVD-SL7G25 | 7KV | 25 mA | 100ns |
| G8FS | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| G10FS | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| G12FS | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| G15FS | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| G20FS | HVD-SL20G25 | 20KV | 25 mA | 100ns |
| G25FS | HVD-SL25G25 | 25KV | 25 mA | 100ns |
| G30FS | HVD-SL30G25 | 30KV | 25 mA | 100ns |
| G2FSA | HVD-SL2G25 | 2KV | 25 mA | 75ns |
| G3FSA | HVD-SL3G25 | 3KV | 25 mA | 75ns |
| G4FSA | HVD-SL4G25 | 4KV | 25 mA | 75ns |
| G5FSA | HVD-SL5G25 | 5KV | 25 mA | 75ns |
| HL300 | HVD-SL3G40 | 3KV | 40 mA | 100ns |
| HL500 | HVD-SL5G40 | 5KV | 40 mA | 100ns |
| HL800 | HVD-SL8G40 | 8KV | 40 mA | 100ns |
| HL1000 | HVD-SL10G40 | 10KV | 40 mA | 100ns |
| HL1200 | HVD-SL12G40 | 12KV | 40 mA | 100ns |
| HVEF8P | - | 8KV | 30 mA | 20ns |
| HVEF10P | - | 10KV | 20 mA | 20ns |
| HVEF12P | - | 12KV | 20 mA | 20ns |
| NV20FP | HVD-SL2G20 | 2KV | 20 mA | 80ns |
| NV30FP | HVD-SL3G20 | 3KV | 20 mA | 80ns |
| NV40FP | HVD-SL4G20 | 4KV | 20 mA | 80ns |
| NV50FP | HVD-SL5G20 | 5KV | 20 mA | 80ns |
| HVRT080 | HVD-SL8G30 | 8KV | 30 mA | 100ns |
| HVRT120 | HVD-SL12G30 | 12KV | 30 mA | 100ns |
| HVRT150 | HVD-SL15G30 | 15KV | 30 mA | 100ns |
| HVRT200 | HVD-SL20G30 | 20KV | 30 mA | 100ns |
| HVRT250 | HVD-SL25G30 | 25KV | 30 mA | 100ns |
| HVRT300 | HVD-SL30G30 | 30KV | 30 mA | 100ns |
| HVRL150 | HVD-SL15G30 | 15KV | 30 mA | 100ns |
| HVRL200 | HVD-SL20G30 | 20KV | 30 mA | 100ns |
| HVRL250 | HVD-SL25G30 | 25KV | 30 mA | 100ns |
| HVRL300 | HVD-SL30G30 | 30KV | 30 mA | 100ns |
| HVRL400 | HVD-SL40G30 | 40KV | 30 mA | 100ns |
| HV07-12B | HVD-SL312 | 12KV | 225 mA | / |
| HV37-08 | HVD-SL308G | 8KV | 210 mA | 150ns |
| HV37-08F | HVD-SL208G | 8KV | 210 mA | 50ns |
| HV37-10 | HVD-SL310G | 10KV | 190 mA | 150ns |
| HV37-10F | HVD-SL310GF | 10KV | 190 mA | 120ns |
| HV37-12 | HVD-SL312G | 12KV | 250 mA | 100ns |
| HV37-12F | HVD-SL312GF | 12KV | 300 mA | 80ns |
| HV37-20 | HVD-SL220G | 20KV | 200 mA | 100ns |
| HV37-20F | HVD-SL220GF | 20KV | 200 mA | 80ns |
| CL03-08 | HVD-SL03-08 | 8KV | 400 mA | 100ns |
| CL03-10 | HVD-SL03-10 | 10KV | 300 mA | 100ns |
| CL03-12 | HVD-SL03-12 | 12KV | 250 mA | 100ns |
| CL03-15 | HVD-SL03-15 | 15KV | 200 mA | 100ns |
| CL03-20 | HVD-SL03-20 | 20KV | 120 mA | 100ns |
| CL03-30 | HVD-SL03-30 | 30KV | 120 mA | 100ns |
| 2CL2FF | HVD-2CL2FF | 8KV | 60 mA | 150ns |
| 2CL2F | HVD-2CL2F | 8KV | 100 mA | / |
| 2CL2FG | HVD-2CL2FG | 10KV | 60 mA | 150ns |
| 2CL2G | HVD-2CL2G | 10KV | 100 mA | / |
| 2CL2FK | HVD-2CL2FK | 10KV | 140 mA | 100ns |
| 2CL2FH | HVD-2CL2FH | 12KV | 60 mA | 150ns |
| 2CL2H | HVD-2CL2H | 12KV | 100 mA | / |
| 2CL2FJ | HVD-2CL2FJ | 15KV | 60 mA | 150ns |
| 2CL2J | HVD-2CL2J | 15KV | 100 mA | / |
| 2cl2fl | HVD-2CL2FL | 15KV | 120 mA | 100ns |
| 2CL2FM | HVD-2CL2FM | 20KV | 100 mA | / |
| 2CL2FP | HVD-2CL2FP | 30KV | 140 mA | 100ns |
| 2CL2FR | HVD-2CL2FR | 35KV | 100 mA | 100ns |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| UX-FBR8 | HVD-2CL8KV / 420 mA | 8KV | 420 mA | / |
| UX-F2CL15 | HVD-2CLG15KV / 150 mA | 15KV | 150 mA | 50ns |
| UX-F15B | HVD-2CLG15KV / 200 mA | 15KV | 200 mA | 50ns |
| UX-F30B | HVD-2CLG30KV / 100 mA | 30KV | 100 mA | 50ns |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| BR2F | HVD-SL2F | 2KV | 900 mA | 100ns |
| BR2 | HVD-SL2 | 2KV | 1000 mA | / |
| BR3F | HVD-SL3F | 3KV | 900 mA | 100ns |
| BR4F | HVD-SL4F | 4KV | 600 mA | 100ns |
| BR4 | HVD-SL4 | 4KV | 850 mA | / |
| BR5F | HVD-SL5F | 5KV | 600 mA | 100ns |
| BR6F | HVD-SL6F | 6KV | 500 mA | 100ns |
| BR8F | HVD-SL8F | 8KV | 400 mA | 100ns |
| BR10F | HVD-SL10F | 10KV | 250 mA | 100ns |
| BRU10SF | HVD-SLU10SF | 10KV | 250 mA | 75ns |
| HV200UF3 | HVD-SL200UF3 | 3KV | 375 mA | 50ns |
| HV200UF4 | HVD-SL200UF4 | 4KV | 375 mA | 50ns |
| HV200UF5 | HVD-SL200UF5 | 5KV | 375 mA | 50ns |
| HV550S08 | HVD-HV600S08 | 8KV | 550 mA | / |
| HV550S10 | HVD-HV600S10 | 10KV | 450 mA | / |
| HV550S12 | HVD-HV600S12 | 12KV | 400 mA | / |
| HV550S15 | HVD-HV600S15 | 15KV | 350 mA | / |
| HV550S20 | HVD-HV600S20 | 20KV | 250 mA | / |
| HV550S25 | HVD-HV600S25 | 25KV | 200 mA | / |
| HV550S30 | HVD-HV600S30 | 30KV | 200 mA | / |
| HV550S45 | HVD-HV600S45 | 45KV | 100 mA | / |
| HVCF25 | HVD-2CLG2.5KV / 1.5A | 2.5KV | 1500 mA | 75ns |
| HVCF50 | HVD-2CLG5KV / 1.2A | 5KV | 1200 mA | 75ns |
| HVCF100 | HVD-2CLG10KV / 0.65A | 10KV | 650 mA | 75ns |
| HVRW1 | HVD-HVRW1 | 1KV | 2500 mA | 150ns |
| HVRW2 | HVD-HVRW2 | 2KV | 1500 mA | 150ns |
| HVRW3 | HVD-HVRW3 | 3KV | 1500 mA | 150ns |
| HVRW4 | HVD-HVRW4 | 4KV | 1000 mA | 150ns |
| HVW3 | HVD-HVRM3 | 3KV | 2000 mA | / |
| UFHV2K | HVD-SL2G550 | 2KV | 550 mA | 75ns |
| UFHV3K | HVD-SL3G400 | 3KV | 400 mA | 75ns |
| UFHV4K | HVD-SL4G350 | 4KV | 350 mA | 75ns |
| EF100 | HVD-SLF100 | 1KV | 600 mA | / |
| EF150 | HVD-SLF150 | 1.5KV | 600 mA | / |
| EF200 | HVD-SLF200 | 2KV | 600 mA | / |
| EG200 | HVD-SLG200 | 2KV | 400 mA | / |
| EG250 | HVD-SLG250 | 2.5KV | 400 mA | / |
| EG300 | HVD-SLG300 | 3KV | 400 mA | / |
| EH300 | HVD-SLH300 | 3KV | 300 mA | / |
| EH350 | HVD-SLH350 | 3.5KV | 300 mA | / |
| EH400 | HVD-SLH400 | 4KV | 300 mA | / |
| EK450 | HVD-SLH450 | 4.5KV | 200 mA | / |
| EK500 | HVD-SLH500 | 5KV | 200 mA | / |
| EK600 | HVD-SLH600 | 6KV | 200 mA | / |
| EM700 | HVD-SLM700 | 7KV | 175 mA | / |
| EM800 | HVD-SLM800 | 8KV | 175 mA | / |
| EP2016 | - | 9KV | 150 mA | / |
| EP2016 | - | 10KV | 150 mA | / |
| ER1100 | HVD-SLP1100 | 11KV | 100 mA | / |
| ER1200 | HVD-SLP1200 | 12KV | 100 mA | / |
| RF160B | HVD-SLF160B | 1.6KV | 500 mA | 250ns |
| RF200B | HVD-SLF200B | 2KV | 500 mA | 250ns |
| RG300B | HVD-SLG300B | 3KV | 350 mA | 250ns |
| RK300B | HVD-SLK300B | 3KV | 150 mA | 250ns |
| RK400B | HVD-SLK400B | 4KV | 150 mA | 250ns |
| RK500B | HVD-SLK500B | 5KV | 150 mA | 250ns |
| RK600B | HVD-SLK600B | 6KV | 150 mA | 250ns |
| RM700B | HVD-SLM700B | 7KV | 125 mA | 250ns |
| RM800B | HVD-SLM800B | 8KV | 125 mA | 250ns |
| RP900B | HVD-SLP900B | 9KV | 100 mA | 250ns |
| RP1000B | HVD-SLP1000B | 10KV | 100 mA | 250ns |
| RR1100B | HVD-SLP1100B | 11KV | 80 mA | 250ns |
| RR1200B | HVD-SLP1200B | 12KV | 80 mA | 250ns |
| RF160A | HVD-SLF160A | 1.6KV | 500 mA | 150ns |
| RF200A | HVD-SLF200A | 2KV | 500 mA | 150ns |
| RG300A | HVD-SLG300A | 3KV | 350 mA | 150ns |
| RK300A | HVD-SLK300A | 3KV | 150 mA | 150ns |
| RK400A | HVD-SLK400A | 4KV | 150 mA | 150ns |
| RK500A | HVD-SLK500A | 5KV | 150 mA | 150ns |
| RK600A | HVD-SLK600A | 6KV | 150 mA | 150ns |
| RM800A | HVD-SLM800A | 8KV | 125 mA | 150ns |
| RP1000A | HVD-SLP1000A | 10KV | 100 mA | 150ns |
| RR1200A | HVD-SLR100A | 12KV | 80 mA | 150ns |
| FB4 | HVD-SL4 | 4KV | 2A | / |
| FB5 | HVD-SL5 | 5KV | 2A | / |
| FBR3 | HVD-SLR3 | 3KV | 1.5A | 250ns |
| FBR3.5 | HVD-SLR3.5 | 3.5KV | 1.5A | 250ns |
| FBR4 | HVD-SLR4 | 4KV | 1.5A | 250ns |
| 3W2 | HVD-HVRM2 | 2KV | 2A | / |
| 3W2.5 | HVD-HVRM2.5 | 2.5KV | 2A | / |
| 3W3 | HVD-HVRM3 | 3KV | 2A | / |
| 3RW2 | HVD-HVRW2 | 2KV | 1.5A | 250ns |
| 3RW2.5 | HVD-HVRW2.5 | 2.5KV | 1.5A | 250ns |
| 3RW3 | HVD-HVRW3 | 3KV | 1.5A | 250ns |
| XL10 | HVD-SL10 | 9KV | 220 mA | / |
| XLR5 | HVD-SLR5 | 5KV | 200 mA | 175ns |
| XLR10 | HVD-SLR10 | 9KV | 200 mA | 175ns |
| XLU12 | HVD-SLU12 | 11KV | 100 mA | 50ns |
| XLR20 | HVD-SLR20 | 18KV | 100 mA | 175ns |
| 5 | - | 5KV | 500 mA | 150ns |
| XMU5 | HVD-SLMU5 | 5KV | 300 mA | 75ns |
| XMU10 | HVD-SLMU10 | 9KV | 300 mA | 75ns |
| DR300 | HVD-SL3G25 | 3KV | 25 mA | 100ns |
| DR500 | HVD-SL5G25 | 5KV | 25 mA | 100ns |
| DR800 | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| DR1000 | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| DR1200 | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| DR1500 | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| DL300 | HVD-SL3G25 | 3KV | 25 mA | 150ns |
| DL500 | HVD-SL5G25 | 5KV | 25 mA | 150ns |
| DL800 | HVD-SL8G25 | 8KV | 25 mA | 150ns |
| DL1000 | HVD-SL10G25 | 10KV | 25 mA | 150ns |
| DL1200 | HVD-SL12G25 | 12KV | 25 mA | 150ns |
| QR12 | HVD-2CL73 | 12KV | 6 mA | 100ns |
| TV6 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| TV8 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| TV10 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| TV12 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| TV14 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| TV16 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| TV20 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| TVR30 | HVD-2CL82 | 30KV | 10 mA | 100ns |
| RUSH103 | HVD-SL200UF3 | 3KV | 200 mA | 50ns |
| RUSH104 | HVD-SL200UF4 | 4KV | 200 mA | 50ns |
| RUSH105 | HVD-SL200UF5 | 5KV | 200 mA | 50ns |
| VT1000 | HVD-SL1000 | 10KV | 50 mA | / |
| VT1200 | HVD-SL1200 | 12KV | 50 mA | / |
| VT1500 | HVD-SL1500 | 15KV | 50 mA | / |
| RVT1000 | HVD-SL10G50 | 10KV | 50 mA | 100ns |
| RVT1200 | HVD-SL12G50 | 12KV | 50 mA | 100ns |
| RVT1500 | HVD-SL15G50 | 15KV | 50 mA | 100ns |
| ROST2008 | - | 8KV | 100 mA | 50ns |
| ROST2010 | - | 10KV | 100 mA | 50ns |
| CRVT150 | HVD-SL15G25B | 15KV | 25 mA | 100ns |
| CRVT200 | HVD-SL20G25B | 20KV | 25 mA | 100ns |
| CRVT250 | HVD-SL25G25B | 25KV | 25 mA | 100ns |
| CRVT300 | HVD-SL30G25B | 30KV | 25 mA | 100ns |
| SL300 | HVD-SL3G40 | 3KV | 40 mA | 100ns |
| SL500 | HVD-SL5G40 | 5KV | 40 mA | 100ns |
| SL800 | HVD-SL8G40 | 8KV | 40 mA | 100ns |
| SL1000 | HVD-SL10G40 | 10KV | 40 mA | 100ns |
| SL1200 | HVD-SL12G40 | 12KV | 40 mA | 100ns |
| SR300 | HVD-SL3G25 | 3KV | 25 mA | 100ns |
| SR500 | HVD-SL5G25 | 5KV | 25 mA | 100ns |
| SR800 | HVD-SL8G25 | 8KV | 25 mA | 100ns |
| SR1000 | HVD-SL10G25 | 10KV | 25 mA | 100ns |
| SR1200 | HVD-SL12G25 | 12KV | 25 mA | 100ns |
| SR1500 | HVD-SL15G25 | 15KV | 25 mA | 100ns |
| 2CL69 | HVD-2CL69 | 4KV | 5 mA | 100ns |
| 2CL70 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| 2CL71 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| 2CL72 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| 2CL73 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| 2CL74 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| 2CL75 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| 2CL76 | HVD-2CL76 | 18KV | 5 mA | 100ns |
| 2CL77 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| 2CL103 | HVD-2CL103 | 9KV | 350 mA | / |
| 2CL104 | HVD-2CL104 | 12KV | 350 mA | / |
| 2CL105 | HVD-2CL105 | 9KV | 450 mA | / |
| 2CL106 | HVD-2CL106 | 12KV | 450 mA | / |
| R3000 | HVD-R3000 | 3KV | 200 mA | / |
| R3000F | HVD-R3000F | 3KV | 200 mA | / |
| R4000 | HVD-R4000 | 4KV | 200 mA | / |
| R4000F | HVD-R4000F | 4KV | 200 mA | / |
| R5000 | - | 5KV | 200 mA | / |
| R5000F | HVD-R5000F | 5KV | 200 mA | / |
| RFC3K | HVD-R3000 | 3KV | 200 mA | / |
| RFC4K | HVD-R4000 | 4KV | 200 mA | / |
| 2CL4 | HVD-2CL69 | 4KV | 5 mA | 100ns |
| 2CL6 | HVD-2CL70 | 6KV | 5 mA | 100ns |
| 2CL8 | HVD-2CL71 | 8KV | 5 mA | 100ns |
| 2CL10 | HVD-2CL72 | 10KV | 5 mA | 100ns |
| 2CL12 | HVD-2CL73 | 12KV | 5 mA | 100ns |
| 2CL14 | HVD-2CL74 | 14KV | 5 mA | 100ns |
| 2CL16 | HVD-2CL75 | 16KV | 5 mA | 100ns |
| 2CL20 | HVD-2CL77 | 20KV | 5 mA | 100ns |
| 2CL703 | HVD-2CL703 | 3KV | 5 mA | 80ns |
| 2CL704 | HVD-2CL704 | 4KV | 5 mA | 80ns |
| T71A | HVD-2CLT71 | 8KV | 5 mA | 80ns |
| T72A | HVD-2CLT72 | 10KV | 5 mA | 80ns |
| T73A | HVD-2CLT73 | 12KV | 5 mA | 80ns |
| T74A | HVD-2CLT74 | 14KV | 5 mA | 80ns |
| T75A | HVD-2CLT75 | 16KV | 5 mA | 80ns |
| TG3508 | HVD-SL3508G | 8KV | 350 mA | 150ns |
| TS01 | HVD-SL3506 | 6KV | 350 mA | / |
| UX-C2B | - | 8KV | 500 mA | 35ns |
| T3512H | HVD-2CL3512 | 12KV | 350 mA | / |
| T4512H | HVD-2CL4512 | 12KV | 450 mA | / |
| T3509 | HVD-2CL3509 | 9KV | 350 mA | / |
| T4509 | HVD-2CL4509 | 9KV | 450 mA | / |
| 2CL3512H | HVD-2CL3512 | 12KV | 350 mA | / |
| 2CL4512H | HVD-2CL4512 | 12KV | 450 mA | / |
| BR2 | HVD-SL2 | 2KV | 1000 mA | / |
| BR4 | HVD-SL4 | 4KV | 1000 mA | / |
| TG1015 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| SHV049 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| 2CLG1015 | HVD-2CL15KV / 100 mA | 15KV | 100 mA | 150ns |
| DD2000 | HVD-SL30F10 | 30KV | 10 mA | / |
| JB99 | HVD-2CL20KV / 20 mA | 20KV | 20 mA | 100ns |
| JB99T | HVD-2CL20KV / 20 mA | 20KV | 20 mA | 100ns |
VRRM = Wiederholte Rückspannung · IO = Durchschnittlicher Ausgangsstrom · trr = Maximale Rückwärtserholungszeit
Marktstatus: HVCA (Dean Technology) ist weiterhin über den Vertrieb erhältlich, jedoch mit langen Lieferzeiten und einem deutlichen Markenaufschlag. HVC bietet die gleichwertige Alternative zum Direktpreis ab Werk mit einer Lieferzeit von 4–6 Wochen.
ERSATZLÖSUNG.
HVCA, EDI, HVC-Kondensator, HVC-Kondensator und HVC-Kondensator Ich habe eine Reihe von Tests durchgeführt, um die Entwicklung von EDI- und HVCA-Lösungen zu unterstützen Das ist alles Strom- und Spannungsversorgung (1 kV bis 35 kV). 발표했습니다. Im Jahr 2018 wurde ein HVC-Kondensator entwickelt, der die HV-Kondensatoren und die HV-Kondensatoren in den letzten Jahren auf den Markt gebracht hat 많은 프로젝트를 맡고 있습니다. Die HVC-Technologie ist in der Lage, die Sicherheit zu gewährleisten. Weitere Informationen finden Sie unter EDI, HVCA und anderen Anbietern 있습니다. HVC Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs-Hochspannungs- und Hochspannungs-Spannungsbauweise 500 kV, 10 mA, 20 A, 35 ns, 2,000 Hz, 사용 주파수는 50 Hz oder 200 kHz. Die HVC-Funktion ist in der aktuellen Version verfügbar. 1) 낮은 누설 전류, 서지 전류, 낮은 역방향 전압, 낮은 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 3) 4) 4) 5) 6) 6) 6) 6) 4) 높은 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C, 175 °C 지역과 남동부 지역에 생산 근거지를 두고 있습니다. 10.01.2019 19.09.2019 Die gewünschte Einstellung wird angezeigt, wenn Sie die gewünschte Funktion verwenden. 다음은 자주 검색되는 고전압 다이오드 부품 번호입니다. Die HVC-Funktion ist in der Lage, die Leistung zu steigern und die Leistung zu steigern. 1) 2CL2FL, 2CL2FM, 2CL2FP, 15 kV oder 30 kV, 100 mA oder 140 mA. HVCA- und EDI-Verbindungen, HVCA- und EDI-Verbindungen, HVCA- und EDI-Verbindungen, 초고주파 전송 전원 치치, 먼지 제주파 전송 전원 전원 니니다. Die HVC-Software hat die höchste Priorität des Unternehmens. 2) VT1500, RVT1000, RVT1200, RVT1500, HVRT300, HVRT120, HVRT150, HVRT200, HVCA-Modell. 3) 2CL77, 20 kV, 5 mA, 2CL70, 2CL71, 2CL72, 2CL75, 2CL79, EDI-Verbindung, HVC-Verbindung. 4) UX-F0B, UX-C2B, UX-F15B, UX-F30B, UX-F2CL15, UX-FOB. Die UX-FOB-Funktion ist nicht verfügbar. Der VRRM 8kV-Standard ist ebenfalls verfügbar. „UX“ ist eine 40-ns-Version der aktuellen Version. 이것은 엑스레이 생성기에 대해 높은 반응 및 높은 효율성을 의미합니다. Maximale Auflösung: 300 kHz, maximale Auflösung: 20 Sekunden. UX-C2B ist ein leistungsstarkes 8-kV- und 500-mA-Netzteil mit 500-mA-Anschluss 사용되고, 대표적인 모델은 파나소닉의 전자레인지입니다. Die HVCA-Zulassung ist nicht möglich. Die HVC-Funktion ist für die Verwendung mit UX-C2B und die damit verbundene Leistung geeignet. 5) RFC4K, RFC3K, R3000, R4000, R5000, R3000F, R4000F, R5000F, T2060, T0504, HVC 제공. 6) TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, TV-Show, 레이저에 주로 사용됨. 2CL70, 2CL71, 2CL72, 2CL73, 2CL74, 2CL75, 2CL76, 2CL77, 2CL4, 2CL6, 2CL8, 2CL10, 2CL12,2CL14,2CL16,2CL20,2CL703,2CL704,T71A,T72A,T73A,T74A,T75A,T77 7) 제습기와 같은 가정용 소형 전자 기기와 복사기, 레이저, 네온광 전원 xnxx TG3508, TS01, UX-C2B, T3512H, T4512H, T3509, T4509, 2CL3512H, 2CL4512H, HVM12, HVM15, 2CL103, 2CL104, HVRT080, HVRT120, HVRT150, HVRT300, T0504, 2CLG3512, FR02-60, CL01-12 8) 매연 정화 치치, 전기 집진기에 주로 사용됨. 2CL2FF, 2CL2FG, 2CL2FH, 2CL2FJ, 2CL2FK, 2CL2FL, 2CL2FM, 2CL2FP, HV37-08, HV37-20, BR2, BR4. CL-, BR-, HVRT-, HVRL-, TG1015-, SHV049-, 2CLG1015-, DD2000-, JB99T-, HVRT200- und HVCA-, EDI- und andere Netzwerkverbindungen Die HVC-Familie hat sich für die Zukunft entschieden 니 다.
TYPISCHE ANWENDUNGEN.
Laser-Netzteile
CO₂- und Festkörperlaser-Ladeschaltungen der 6-kV-Klasse.
Elektrostatische Kontrolle
Stromversorgung für elektrostatische Abscheidung und Elektrofilter.
Forschung & Instrumentierung
Kundenspezifische Hochspannungsmultiplikatoren für Labor- und Universitätssysteme.
FAQ.
Kann HVC die Modelle DV6P, DV8P, DV10P, G6FS, G7FS und G8FS ersetzen?
Ja – HVC bietet pinkompatible Ersatzbauteile für DV6P, DV8P, DV10P, G6FS, G7FS und G8FS mit identischer Bauform sowie passenden Spannungs- und Stromwerten. Jedes Bauteil wird auf Impulsfestigkeit mit dem 1.6-Fachen der Nennspannung geprüft.
Wie lange sind Lieferzeit und Mindestbestellmenge für DV6P?
Standardteile werden innerhalb von 4–6 Wochen versandt, Muster sind ohne Mindestbestellmenge erhältlich. Die Mindestbestellmenge für die Produktion ist flexibel – kontaktieren Sie unseren Vertrieb, um Ihre individuellen Anforderungen zu besprechen.
Wie kann ich überprüfen, ob das Ersatzteil zu meinem Schaltkreis passt?
Fordern Sie ein kostenloses Muster an und testen Sie es im laufenden Betrieb, bevor Sie es einsetzen. HVC stellt Datenblätter und Querverweisdokumentationen für jedes Ersatzteil bereit.
WEITERE ANLEITUNGEN ZUM AUSTAUSCH VON HLK-KABELN.
Hochspannungsdiodenhersteller | 10 kV–30 kV Hochspannungsgleichrichter | Alternative zu HVCA, EDI, VMI
Leitfaden ansehen →
Alternativer Ersatz für HVCA-HV-Diode von UFHV2K UFHV3K UFHV4K
Leitfaden ansehen →
Alternativer Ersatz für HVCA-HV-Diode von HV550S15 HV550S20 HV550S25 HV550S30 HV550S45 HVCF25 HVCF50
Leitfaden ansehen →
Alternativer Ersatz für die HVCA-HV-Diode von 2CL2FP 2CL2FR 2CL105 2CL106
Leitfaden ansehen →
Technische Leitfäden & Querverweise
WEITERFÜHRENDE LITERATUR.
2026-10-10
Diagnose von HV-Kondensatordiodenfehlern bei der Reparatur von CO2-Laserversorgungen
Ein kurzgeschlossener Filterkondensator ist meist die Ursache: Eine Diode mit 100 µA Sperrstrom erhöht den Restwelligkeitsstrom so lange, bis die Erwärmung des Kondensators durch den ESR diesen zerstört. Dieser Leitfaden beschreibt die Ausfallarten von Kondensatoren, Widerständen und Dioden sowie vier Diagnosestufen und Scan-Grenzwerte.
Leitfaden lesen →
2026-10-09
Isolations- und Leckagegrenzen für medizinische CO2-Lasernetzteile
Ein medizinischer CO₂-Laser mit 10 kV Ausgangsspannung, dessen Leckstrom innerhalb der 100 µA-Grenze für Typ B liegt, benötigt einen Isolationspfad von über 100 MΩ, in feuchten Räumen von 500 MΩ bis 1 GΩ. Dieser Leitfaden behandelt das Leckstrommodell, die Teilentladungsabschirmung bei 5 pC, die Transformatorabschirmung und die ausfallsichere Verriegelungskette.
Leitfaden lesen →
2026-10-08
Auswirkungen der Sperrverzögerung von Hochspannungsdioden auf die Pulsform von CO2-Lasern
Bei einer Sperrspannung von 10 kV, einem Erholungsstrom von 1 A und einer Erholungszeit von 500 ns brennt eine Diode bei 100 kHz 250 W durch. Es werden die Erholungsgleichungen, die sechs Feldausfallarten sowie die Grenzwerte für Erholungszeit, Ladung und Leckstrom angegeben, die den Spannungsspitzenwert innerhalb der Nennleistung des Bauteils halten.
Leitfaden lesen →
2026-10-06
Isolationsbarriereprüfungen jenseits der Spannungsfestigkeit für medizinische Geräte
Eine Nennspannung von 4000 V AC beweist lediglich, dass der Kondensator den Versandtag überstanden hat. Die folgenden fünf Prüfungen sagen den Rest voraus: Beginn der Teilentladung beim 1.8-fachen des Spitzenwerts, Isolationswiderstand über 10 GΩ bei 85 °C, korrigierte Kriechspannung, Temperaturwechselbeständigkeit und Salzsprühnebelbeständigkeit.
Leitfaden lesen →